Phospho Glycerate Kinase (PGK) assay

Description
PGK deficiency is a very rare cause of hereditary nonspherocytic haemolytic anaemia. Other more common causes, such as PK deficiency or G6PD deficiency should be eliminated first
Reference range

247 – 392 IU/g Hb

Testing site
Synnovis : Blood Sciences : Blackfriars Hub
Laboratory
Red Cell
Sample type and volume required

Minimum 1 ml EDTA blood. FBC and reticulocyte count must be performed and results sent with samples. If more than one enzyme assay is required then > 1.0 ml of blood will be required.

Special sample instructions

Blood transfusion within the last four months will affect results. Any red cell transfusion given must be declared on the request form.

Raised reticulocyte levels and/or raised Wbc levels may affect assay.

Storage and transport

Samples can be sent first class post. Samples must be received in the laboratory within 3 days of collection. If there is a delay in sending store at 4°C and send a normal sample collected on the same day to act as a travel control.

Turnaround time

10 working days

Cost

Please contact Business Development for pricing enquiries

Time limit for extra tests

Depends on tests required. Contact laboratory for further details.

Contacts

Specialist Red Cell Laboratory

Phone – 020 4591 0045

Synnovis Hub

Floor 2

Friars Bridge Court

41-43 Blackfriars Road

London SE1 8NZ

Last updated: