Living donor crossmatch

Description
Flow cytometry analysing IgG binding to donor T and B lymphocytes from peripheral blood
Clinical details
In solid organ transplantation the presence of HLA donor specific antibodies is associated with graft loss and graft dysfunction. Flow cytometric (FCXM) crossmatch tests are used to identify HLA donor specific antibodies. A crossmatch test is performed in living kidney transplantation
Related condition
Reference range
> 2.3 - positive
Units
RMF
Synonyms
crossmatch
Testing site
Synnovis : Reference Services : Guy's Hospital
Laboratory
Clinical Transplantation Laboratory
Sample type and volume required
donor - 20mls EDTA blood recipient - 5ml clotted blood
Call in advance
Call 020 7188 1540 to book in a crossmatch
Special sample instructions
samples should be bled on day of testing
Storage and transport
UN3373 packaging
Turnaround time
2 days
Time limit for extra tests
none
Contacts

Clinical Transplantation Laboratory at Guy’s Hospital
Phone: 020 7188 1540
Clinical Transplantation Laboratory
Guy’s Hospital
Borough Wing – 3rd Floor
Great Maze Pond
London SE1 9RT

Email: gstt.ctl@nhs.net

Last updated: